17
CG10 Burner Manual
Table 2. Initial burner settings
Notice: The settings in this chart are for reference only. The actual conditions at the installation may require further
adjustment by the fully qualifi ed and experienced start-up technician.
Notice: The light-off rate must not be set below the low fi re recommendation. Lower rates will lengthen the time it takes for
gas to get to the burner head and may cause ignition failures.
Section: Start the Burner
Furnace Pressure 0” W. C. .25” W. C. .50” W. C. 1.00” W. C.
Firing Rate MBH
Burner Model
Running Manifold
Gas Pressure, In. WC
Low Fire Start Gas
Pressure, In. WC
Shutter Setting
Band Setting
Running Manifold
Gas Pressure, In. WC
Low Fire Start Gas
Pressure, In. WC
Shutter Setting
Band Setting
Running Manifold
Gas Pressure, In. WC
Low Fire Start Gas
Pressure, In. WC
Shutter Setting
Band Setting
Running Manifold
Gas Pressure, In. WC
Low Fire Start Gas
Pressure, In. WC
Shutter Setting
Band Setting
Stepped Spud Head Confi guration
300 CG10.1S 1.0 0.5 3 0 1.3 0.6 3 0 1.5 0.8 4 0 2.0 1.0 6 0
350 CG10.1S 1.4 0.7 4 0 1.6 0.8 4 0 1.9 0.9 5 0 2.4 1.2 7 0
400 CG10.2S 1.1 0.5 4 0 1.3 0.7 4 0 1.6 0.8 5 0 2.1 1.0 6 0
450 CG10.2S 1.4 0.7 5 0 1.7 0.8 6 0 1.9 1.0 7 0 2.4 1.2 9 0
500 CG10.3S 1.2 0.6 6 0 1.5 0.7 7 0 1.7 0.9 8 0 2.2 1.1 10 1
550 CG10.3S 1.3 0.7 8 0 1.6 0.8 9 0 1.8 0.9 10 0 2.3 1.2 - -
600 CG10.4S 2.5 1.3 5 0 2.8 1.4 6 0 3.0 1.5 7 0 3.5 1.8 9 0
700 CG10.4S 3.4 1.7 7 0 3.6 1.8 9 0 3.9 1.9 10 0 4.4 2.2 10 3
800 CG10.5S 3.1 1.6 10 0 3.4 1.7 10 1 3.6 1.8 10 1 4.1 2.1 10 3
900 CG10.5S 4.0 2.0 10 3 4.2 2.1 10 4 4.5 2.2 10 4 5.0 2.5 10 6
1000 CG10.6S 3.2 1.6 10 0 3.4 1.7 10 2 3.7 1.8 10 3 4.2 2.1 10 6
1100 CG10.6S 3.9 1.9 10 2 4.1 2.1 10 4 4.4 2.2 10 5 4.9 2.4 10 10
1200 CG10.6S 4.6 2.3 10 6 4.9 2.4 10 8 5.1 2.6 10 10 - - - -
Spinner Head Confi guration
300 CG10.1 1.5 0.8 3 0 1.8 0.9 3 0 2.0 1.0 4 0 2.5 1.3 5 0
350 CG10.1 2.0 1.0 5 0 2.3 1.1 6 0 2.5 1.3 8 0 3.0 1.5 10 1
400 CG10.2 1.6 0.8 4 0 1.8 0.9 4 0 2.1 1.0 5 0 2.6 1.3 6 0
450 CG10.2 2.0 1.0 4 0 2.2 1.1 4 0 2.5 1.2 5 0 3.0 1.5 8 0
500 CG10.3 1.5 0.8 5 0 1.8 0.9 5 0 2.0 1.0 6 0 2.5 1.3 8 0
550 CG10.3 1.9 0.9 7 0 2.1 1.1 8 0 2.4 1.2 9 0 2.9 1.4 10 1
600 CG10.4 1.1 0.6 6 0 1.4 0.7 7 0 1.6 0.8 8 0 2.1 1.1 10 0
700 CG10.4 1.5 0.8 9 0 1.8 0.9 10 0 2.0 1.0 10 1 2.5 1.3 10 4
800 CG10.5 1.5 0.7 9 0 1.7 0.9 10 1 2.0 1.0 10 3 2.5 1.2 10 6
900 CG10.5 1.9 0.9 10 1 2.1 1.1 10 3 2.4 1.2 10 4 2.9 1.4 10 9
1000 CG10.6 1.8 0.9 10 2 2.1 1.0 10 4 2.3 1.2 10 5 2.8 1.4 10 9
1100 CG10.6 2.2 1.1 10 4 2.5 1.2 10 6 2.7 1.4 10 7 - - - -
1200 CG10.6 2.7 1.3 10 6 2.9 1.5 10 8 3.2 1.6 10 10 - - - -